Folding Stair Troubleshooting 

Panel door does not close all the way
Check to see if stair was installed square.

The bolt attaching long arm of the spring arm to the side of the ladder may be too tight and needs to be loosened 1/2 turn. Also put a very little oil on areas where metal parts are rubbing against themselves.
Spring arms are bent inward
Depending on the amount of use, some parts will get loose from wear. These parts may be ordered from the factory. You will need the following information: panel door size, date on stair, number of treads or steps in middle section and whether the treads are painted.
Wood on the ladder near the section hinges has cracked
The ladder was not trimmed to the correct length. A properly trimmed ladder must show all sections in a straight line. See installation instructions for the proper procedure. 